Difference between revisions of "WorkMan HVS - Presales"

From WorkManSoft Wiki
Jump to navigationJump to search
 
(10 intermediate revisions by the same user not shown)
Line 10: Line 10:
  
 
== Requirements ==
 
== Requirements ==
 +
 +
=== Windows Requirements ===
  
 
* Open TCP and UDP ports both directions between server and PBX.
 
* Open TCP and UDP ports both directions between server and PBX.
 
* 2 GB memory or more is recommended.
 
* 2 GB memory or more is recommended.
 
* 2 GHz or faster processor.
 
* 2 GHz or faster processor.
 +
* At least 10 GB of free space on C-drive.
 
* QoS - Quality of Service for SIP traffic is recommended.
 
* QoS - Quality of Service for SIP traffic is recommended.
 
* For serial/COM-port you must either have physical port or use a Moxa-box (or similar).
 
* For serial/COM-port you must either have physical port or use a Moxa-box (or similar).
  
=== Windows Versions ===
+
==== Windows Versions ====
  
 
These can run on a physical server or a virtualized one.  
 
These can run on a physical server or a virtualized one.  
 
Only issue when running virtualized is when using serial COM-port to communicate to PMS. This can be overcome by Moxa-box.
 
Only issue when running virtualized is when using serial COM-port to communicate to PMS. This can be overcome by Moxa-box.
 +
All applications are 32-bit but run on 64-bit editions of Windows.
  
==== Recommended OS ====
+
===== Recommended OS =====
  
* Windows 2012 R2
+
* Windows 2019
* Windows 2012
+
* Windows 11
 
* Windows 10
 
* Windows 10
  
==== Obsolete OS ====
+
===== Obsolete OS =====
  
 
Earlier versions of these was tested ok, but will no longer be tested.
 
Earlier versions of these was tested ok, but will no longer be tested.
Line 65: Line 69:
 
| 2016
 
| 2016
 
| OK
 
| OK
| Test only
+
| Yes
 
| 2.2.1.17
 
| 2.2.1.17
 
| Not tested
 
| Not tested
Line 73: Line 77:
 
| 2016-06-10
 
| 2016-06-10
 
| OK
 
| OK
| Test only
+
| Yes
 
| 2.2.1.17
 
| 2.2.1.17
 
| Not tested
 
| Not tested
Line 117: Line 121:
 
|-
 
|-
 
| AX32 (generic)
 
| AX32 (generic)
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
 
| [[WorkMan HVS - Protocol AX32|AX32]]
 
| [[WorkMan HVS - Protocol AX32|AX32]]
| ?
+
| COM, IPCLIENT
 
|  
 
|  
 
|  
 
|  
Line 129: Line 133:
 
|-
 
|-
 
| Comtrol (generic)
 
| Comtrol (generic)
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
 
| [[WorkMan HVS - Protocol Comtrol|Comtrol]]
 
| [[WorkMan HVS - Protocol Comtrol|Comtrol]]
| ?
+
| IPCLIENT
 
|  
 
|  
 
|  
 
|  
Line 142: Line 146:
 
| DIP (generic)
 
| DIP (generic)
 
|style="text-align:center;" | Yes
 
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
 
|style="text-align:center;" | Yes
 
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
 
| [[WorkMan HVS - Protocol DIP|DIP]]
 
| [[WorkMan HVS - Protocol DIP|DIP]]
| ?
+
| COM, IPCLIENT, IPSERVER
 
|  
 
|  
 
|  
 
|  
Line 159: Line 163:
 
|style="text-align:center;" | Yes
 
|style="text-align:center;" | Yes
 
| [[WorkMan HVS - Protocol FIAS|FIAS]]
 
| [[WorkMan HVS - Protocol FIAS|FIAS]]
| ?
+
| IPCLIENT
 
|  
 
|  
 
|  
 
|  
Line 165: Line 169:
 
|-
 
|-
 
| Cenium
 
| Cenium
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
 
| [[WorkMan HVS - Protocol Comtrol|Comtrol]]
 
| [[WorkMan HVS - Protocol Comtrol|Comtrol]]
| TCP/IP
+
| IPCLIENT
 
|  
 
|  
 
|  
 
|  
Line 177: Line 181:
 
|-
 
|-
 
| [[WorkMan HVS - Hoist Hotsoft|Hoist Hotsoft]] (older)
 
| [[WorkMan HVS - Hoist Hotsoft|Hoist Hotsoft]] (older)
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
 
| [[WorkMan HVS - Protocol DIP|DIP]]
 
| [[WorkMan HVS - Protocol DIP|DIP]]
| RS232, TCP/IP*
+
| COM, IPCLIENT
 
|  
 
|  
 
|  
 
|  
Line 189: Line 193:
 
|-
 
|-
 
| Hoist Hotsoft v 8
 
| Hoist Hotsoft v 8
 +
|style="text-align:center;" | Yes
 +
|style="text-align:center;" | -
 +
|style="text-align:center;" | Yes
 
|style="text-align:center;" | Yes
 
|style="text-align:center;" | Yes
 
|style="text-align:center;" | Yes
 
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
 
|style="text-align:center;" | ?
 
|style="text-align:center;" | ?
 
 
| [[WorkMan HVS - Protocol FIAS|FIAS]]
 
| [[WorkMan HVS - Protocol FIAS|FIAS]]
| ?
+
| IPCLIENT
 
|  
 
|  
 
| 2015-12-23
 
| 2015-12-23
Line 207: Line 211:
 
|style="text-align:center;" | Yes
 
|style="text-align:center;" | Yes
 
| [[WorkMan HVS - Protocol FIAS|FIAS]]
 
| [[WorkMan HVS - Protocol FIAS|FIAS]]
| TCP/IP
+
| COM, IPCLIENT
 
|  
 
|  
| 2016-10-27
+
| 2017-10-20
| Supported using the FIAS-protocol
+
| FIAS protocol is used for Oracle Fidelio and other PMS that supports the FIAS-protocol.
 
|-
 
|-
| Protel (using FIAS)
+
| Protel
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
 
| [[WorkMan HVS - Protocol FIAS|FIAS]]
 
| [[WorkMan HVS - Protocol FIAS|FIAS]]
| ?
+
| COM, IPCLIENT
 
|  
 
|  
| 2016-11-11
+
|  
| Untested but supports the FIAS-protocol
+
| Possible support using FIAS, unverified at this time.
 
|-
 
|-
 
| Techotel Picasso
 
| Techotel Picasso
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
|style="text-align:center;" | ?
+
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
 
| [[WorkMan HVS - Protocol DIP|DIP]]
 
| [[WorkMan HVS - Protocol DIP|DIP]]
| ?
+
| IPSERVR
 
|  
 
|  
| NA
+
| 2017-10-20
 
| Supported using the DORO-protocol,  
 
| Supported using the DORO-protocol,  
 
|-
 
|-
| Spectra
+
| Spektra
 
|style="text-align:center;" | Yes
 
|style="text-align:center;" | Yes
|style="text-align:center;" | ?
+
|style="text-align:center;" | -
 
|style="text-align:center;" | Yes
 
|style="text-align:center;" | Yes
 
|style="text-align:center;" | -
 
|style="text-align:center;" | -
 
|style="text-align:center;" | -
 
|style="text-align:center;" | -
| [[WorkMan HVS - Protocol DIP|DIP]]
+
| [[WorkMan HVS - Protocol FIAS|FIAS]]
| ?
+
| IPCLIENT
 +
|
 +
| 2017-10-20
 
|  
 
|  
| 2016-09-09
 
| Currently untested but are having pending implementations with them.
 
 
|}
 
|}
  
 
* TCP/IP* You can use a virtual TCP/IP to RS232 converter or a Moxa box to talk TCP/IP to the box which in turn translates it to RS232.
 
* TCP/IP* You can use a virtual TCP/IP to RS232 converter or a Moxa box to talk TCP/IP to the box which in turn translates it to RS232.
 
* Callcharge Price is a feature of HVS 2017
 
* Callcharge Price is a feature of HVS 2017
 +
* COM = Serial COM-port, RS232
 +
* IPCLIENT = TCP/IP Client connecting to a remote TCP/IP server
 +
* IPSERVER = HVS acts as a TCP/IP server and PMS connects to it
  
 
=== Unsupported ===
 
=== Unsupported ===
Line 268: Line 275:
 
| 2016-09-19
 
| 2016-09-19
 
| Requested feedback from them if we can integrate.
 
| Requested feedback from them if we can integrate.
 
|-
 
| Protel
 
| http://www.protel.net/
 
| 2015-12-23
 
| Currently no information on what protocol they support. Attempting to establish contact with them.
 
 
|}
 
|}
  

Latest revision as of 11:13, 3 March 2023

About

WorkMan HVS is a fairly advanced installation since it require many parties to be included namely:

  • You (reseller)
  • Us (WorkManSoft/manufacturer of WorkMan HVS)
  • Supplier of PMS-system
  • Customer (the hotel)
  • Tech-staff from customer

Requirements

Windows Requirements

  • Open TCP and UDP ports both directions between server and PBX.
  • 2 GB memory or more is recommended.
  • 2 GHz or faster processor.
  • At least 10 GB of free space on C-drive.
  • QoS - Quality of Service for SIP traffic is recommended.
  • For serial/COM-port you must either have physical port or use a Moxa-box (or similar).

Windows Versions

These can run on a physical server or a virtualized one. Only issue when running virtualized is when using serial COM-port to communicate to PMS. This can be overcome by Moxa-box. All applications are 32-bit but run on 64-bit editions of Windows.

Recommended OS
  • Windows 2019
  • Windows 11
  • Windows 10
Obsolete OS

Earlier versions of these was tested ok, but will no longer be tested.

  • Windows 2008 R2, supported with SLA
  • Windows 2008
  • Windows 2003
  • Windows 8, supported with SLA
  • Windows 7, supported with SLA
  • Windows Vista
  • Windows XP

Licenses needed with Avaya IP Office

  • 3rd party TAPI
  • SIP-trunk licenses.
  • Contact your Avaya-reseller for any additional licenses that might be needed.

PBX

IP Office

Release Updated Status Production Voice Ver AVIO Config Ver Info
10.0.x 2016 OK Yes 2.2.1.17 Not tested Requires HVS Voice 2.2.1.17.
9.1.7 Server Edition 2016-06-10 OK Yes 2.2.1.17 Not tested Requires HVS Voice 2.2.1.17.
9.1.6 2016-06-10 OK Yes 2.2.1.17 Not tested Issues with SIP-RPORT not properly supported with earlier versions of voice. Should be solved by workaround in HVS Voice 2.2.1.17.
8.0.443001, IP 500 V2 2016-06-10 OK Yes 2.x Not tested

PMS - Property Management Systems

Supported

PMS / Hotelsystems Callcharge Duration Callcharge Price Maidstatus/ Cleaningcode Wakeup from PMS Wakeupstatus to PMS Protocol Transport URL Updated Info
AX32 (generic) Yes - Yes - - AX32 COM, IPCLIENT
Comtrol (generic) Yes - Yes Yes Yes Comtrol IPCLIENT
DIP (generic) Yes - Yes - - DIP COM, IPCLIENT, IPSERVER
FIAS(generic) Yes Yes Yes Yes Yes FIAS IPCLIENT
Cenium Yes - Yes Yes Yes Comtrol IPCLIENT
Hoist Hotsoft (older) Yes - Yes - - DIP COM, IPCLIENT
Hoist Hotsoft v 8 Yes - Yes Yes Yes FIAS IPCLIENT 2015-12-23 Supported using the FIAS-protocol
Oracle Fidelio / Opera/Suite 8 (Micros-Fidelio) Yes Yes Yes Yes Yes FIAS COM, IPCLIENT 2017-10-20 FIAS protocol is used for Oracle Fidelio and other PMS that supports the FIAS-protocol.
Protel Yes Yes Yes Yes Yes FIAS COM, IPCLIENT Possible support using FIAS, unverified at this time.
Techotel Picasso Yes - Yes - - DIP IPSERVR 2017-10-20 Supported using the DORO-protocol,
Spektra Yes - Yes - - FIAS IPCLIENT 2017-10-20
  • TCP/IP* You can use a virtual TCP/IP to RS232 converter or a Moxa box to talk TCP/IP to the box which in turn translates it to RS232.
  • Callcharge Price is a feature of HVS 2017
  • COM = Serial COM-port, RS232
  • IPCLIENT = TCP/IP Client connecting to a remote TCP/IP server
  • IPSERVER = HVS acts as a TCP/IP server and PMS connects to it

Unsupported

These manufacturers are currently unsupported meaning that we don't have any integration up and running. They might support general protocols such as Comtrol, FIAS et.c. but we can't confirm it.

PMS URL Updated Info
Hotellinx http://www.hotellinx.com/ 2016-09-19 Requested feedback from them if we can integrate.